Why DC HQS Inspections Fail — And How to Pass the First Time

Before DCHA pays a dollar of rent, your unit has to pass a Housing Quality Standards (HQS) inspection. A failed inspection means a re-inspection weeks later — and every week the unit sits empty is rent you never get back. Here are the issues that fail DC units most often, and a room-by-room checklist to pass on the first visit.

The most common reasons units fail

Safety devices

  • Smoke detector missing, dead, or not on every level and near each sleeping area
  • Carbon monoxide detector missing where there is gas heat, a gas stove, or an attached garage
  • Fire extinguisher missing where the unit requires one

Electrical

  • No GFCI protection on outlets near the kitchen sink, bathroom, or exterior
  • Missing or cracked cover plates on outlets and switches
  • Exposed wiring, open junction boxes, or a double-tapped breaker
  • An outlet or light that simply does not work in a habitable room

Paint & surfaces

  • Peeling, chipping, or flaking paint — a hard fail in any unit built before 1978 (lead-paint rule)
  • Damaged plaster or drywall that exposes a hazard
  • Trip hazards: torn flooring, loose tile, or a broken threshold

Plumbing & heat

  • Water heater with no temperature/pressure-relief (TPR) discharge pipe
  • Leaks under a sink, a slow drain, or no hot water
  • A room with no permanent, adequate heat source

Windows, doors & stairs

  • A window that will not open, will not stay up, or is painted shut in a bedroom (egress)
  • Missing or torn window screens where required
  • No handrail on a stairway of four or more steps, or a loose/wobbly rail
  • Security bars on a bedroom window with no quick-release from the inside
  • An exterior door that does not lock, or a missing deadbolt

The gotchas that surprise experienced landlords

  • Every stove burner and the oven must work — and the burner knobs must be present.
  • Each outlet counts: a bedroom generally needs at least two working outlets (or one outlet plus a permanent light).
  • A missing refrigerator or a fridge that will not hold temperature fails, even if the tenant plans to bring their own.
  • The unit number/address must be visible from the street for some DCHA inspectors.
  • Mini-blind or window-covering cords within a child’s reach can be flagged.
  • A cracked window pane fails even if the window operates fine.

Pass on the first try

  1. Walk the unit with this list a week before the inspection — not the morning of.
  2. Put fresh batteries in every smoke and CO detector, and test each one.
  3. Fix any peeling paint completely; for pre-1978 units, assume lead-paint scrutiny.
  4. Confirm every outlet, switch, burner, and the oven works, with all cover plates on.
  5. Check GFCI outlets near water actually trip and reset.
  6. Make sure every window opens, stays open, and locks; replace cracked panes and torn screens.
  7. Verify the water heater has a TPR discharge pipe and there are no leaks under sinks.

General guidance based on HUD Housing Quality Standards. DCHA inspectors have final say and requirements can change — always confirm current standards with DCHA for your specific unit.