HQS Inspection Checklist for DC Landlords
Pass your Housing Quality Standards inspection the first time. This comprehensive checklist covers all HUD requirements for Section 8 properties in Washington DC.
Common Fail Points
- !Missing or non-working smoke detectors on each level
- !Missing GFCI outlets near water sources
- !Missing electrical outlet/switch cover plates
- !Peeling or chipping paint (especially in pre-1978 homes)
- !Hot water heater relief valve with PVC pipe (must be copper/galvanized)
- !Double-keyed deadbolts (fire safety violation)
- !Non-working or leaking plumbing fixtures
- !Stove not secured with anti-tip bracket
- !Refrigerator door seal not tight
- !Bathroom without exhaust fan or openable window
Unit vacant and free of debris
The unit must be empty/vacant from previous tenant, and free and clear of all furnishings and debris
Working smoke detectors on each level
There must be working smoke detectors properly mounted on each level of the unit including the basement and walk-up attics
All construction/rehabilitation completed
All construction/rehabilitation (painting, carpet replacement, etc.) must be completed
Unit in clean and sanitary condition
The entire unit shall be in a clean and sanitary condition
Unit freshly painted
The entire unit must be freshly painted
Utilities turned on
Utilities (water, gas, electric) must be turned on for the completion of the inspection
No chipping/peeling paint or wall defects
No chipping or peeling paint, cracks, holes or loose plaster inside or outside the unit
Wood surfaces properly painted and intact
Interior and exterior wood surfaces shall be properly painted and kept intact at all times
Permanently installed working heating system
There must be a permanently installed working heating system
Hot water heater with proper relief valve
The hot water heater tank must have a temperature pressure relief valve with downward discharge pipe made of galvanized steel or copper tubing that is between 6-8 inches from the floor or directed outside the unit. No PVC allowed. CPVC is acceptable.
No plumbing leaks
There must not be any plumbing leaks
P-traps on all plumbing fixtures
All plumbing fixtures must have P-traps to prevent sewer gas from leaking into the unit
Floor covering in good condition
The floor covering cannot be torn or have holes that can cause someone to trip. Carpets if installed shall be clean and free of stains.
Electrical outlets/switches with cover plates
All electrical outlets/switches must have cover plates and be in good working condition
GFCIs working properly
All ground fault circuit interrupters (GFCIs) must work properly
Ground floor windows and doors with working locks
All ground floor windows and exterior doors shall open and close as designed and must have working locks
No double-keyed deadbolts
Double-keyed dead bolts are not permitted
Security bars with quick release
All security bars and windows must have a quick release mechanism
Sliding glass door security
All sliding glass doors must have a lock or security bar on the door that works
Two means of fire egress per living space
Each living space must have two means of fire egress (i.e. door & window)
Windows and doors weather tight
Windows and doors shall be weather tight with glass free of cracks to prevent wind, air or rain penetration
No bedrooms with furnaces or gas meters
No room which contains a furnace, open flame heating unit without proper ventilation or gas meter is designated as a bedroom
Bedroom minimum size and access
Bedrooms shall have at least seventy (70) square feet of floor space and a separate entrance without going through another bedroom
Stove clean, working, and secured
Stove must be clean and in working order and secured
Refrigerator clean and working
Refrigerator must be clean and be in working order with a good door seal
Hot and cold running water
Hot and cold running water in the kitchen and bathroom(s)
Working shower or bathtub
There must be a shower or bathtub that works
Flush toilet - working and secured
There must be a flush toilet that works, is securely mounted and does not leak
Bathroom ventilation
The bathroom must have either an outside window or an exhaust fan vented to the outside
No plugged drains
There must not be any plugged drains (check for slow drains)
Address visible with proper lighting
House or apartment shall be properly numbered or lettered with the proper illumination (lighting)
Walkway to unit
There must be stepping stones or walkway to the unit
Roof does not leak
The roof must not leak. Indications of a leak are discolorations or stains on the ceiling.
Common areas safe and lit
All common hallways, walkways, and parking areas shall be free of cracks and tripping hazards and properly illuminated
Grass/weeds under 4 inches
Weeds and grass shall be less than four (4) inches in height
Garbage containers with covers
All units shall have adequate garbage containers with covers
Stairs and railings secure
If there are stairs and railings, they must be secure
Handrails on 4+ exterior stairs
Four or more exterior stairs must have handrails 34 inches to 38 inches from the ground
Guard rails on elevated areas
Walk offs or porches 30 inches above grade must have guard rails 36 inches from the ground
Important DCHA Notes
- All utilities (water, gas, electric) must be ON during inspection
- Unit must be vacant and move-in ready - completely empty of previous tenant belongings
- Owner must correct all deficiencies within 30 days
- Annual inspections are required for continued HCVP participation
- Emergency fails (no heat, no water, gas leaks) require immediate attention
- This checklist covers common violations - refer to DCMR Title 14 and HUD HQS for complete requirements
Note: If your property fails inspection, you have 30 days to correct deficiencies and schedule a re-inspection.